Technical data

230V 1-Phase

Engine data

Power 90 W
Rotation speed 1360 RPM
Nr. of poles 4
Rated current 1,1 A
Capacitor 5 µF

Other data

Weight 4+0,4kg/100mm
Max work load 4000 N
Max static load 5000 N
Stroke lengths 100/200/300/400 & 500mm
Safety norm IP 55
Ambient temp. -20 to +60 degrees C

End stops

The actuator is equipped with an end position stop to prevent jamming, for example if the limit states would be crossed or at the adjustment of these.

Ratio

The transmission of power between motor and screw is performed with a synchronous transmission belt. The velocity can be varied with three different ratios;
1:1, 1.8:1 and 3.5:1

Performance and material

The outer tube and gear box is manufactured in anodized aluminum and the nut tube in chromium-plated steel.

Brake

Loads exceeding 500N requires a brake. The brake is an electromagnetic spring pressure brake.

Limit switches

Limit switches is a reed contact type. These are assembled on the actuators outer tube and shall not be used for direct switching of or closing of motor counter flow. For this, use middle circuit breakers.

Intermittency factor

As standard, the actuator is equipped with a starting capacitor of 5uF. The actuator can be operated intermittently at 10% with full load. If the actuator is to be run more often or with many starts, a smaller capacitor is recommended.

400V 3-Phase

Engine data

Power 90 W
Rotation speed 1400 RPM
Nr. of poles 4
Rated current 0,34 A

Other data

Weight 5,8+0,4kg/100mm
Max work load 4000 N
Max static load 5000 N
Stroke lengths 100/200/300/400 & 500mm
Safety norm IP 55
Ambient temp. -20 to +60 degrees C

End stops

The actuator is equipped with an end position stop to prevent jamming, for example if the limit states would be crossed or at the adjustment of these.

Ratio

The transmission of power between motor and screw is performed with a synchronous transmission belt. The velocity can be varied with three different ratios;
1:1, 1.8:1 and 3.5:1

Performance and material

The outer tube and gear box is manufactured in anodized aluminum and the nut tube in chromium-plated steel.

Limit switches

Limit switches is a reed contact type. These are assembled on the actuators outer tube and shall not be used for direct switching of or closing of motor counter flow. For this, use middle circuit breakers.

Brake

Loads exceeding 500N requires a brake. The brake is an electromagnetic spring pressure brake.